Glass Lined Piping Systems
References: GL® Heat Exchange Applications (Double Tube)
1. Cooling Applications
|
|
|
Application |
Temp. |
Pressure (kg/cm2) |
Pipe Shell |
Glass |
Pipe Size (mm) |
Comments
|
|
1 |
a |
Acetylene
+ condensed gas |
43¨30 |
0.5 |
STPG38 Sch40 |
STD |
100 |
|
|
b |
Cooling
water |
28¨29 |
2 |
|
|
150 |
|
|
|
2 |
a |
HCl |
100¨40 |
|
STD |
STD |
25 |
|
|
b |
Industrial
water |
30¨40 |
3 |
|
|
50 |
|
|
|
3 |
a |
HCl77%
toluene 21% |
45¨5 |
ATM |
STD |
STD |
50 |
|
|
b |
Ethylene
glycol |
-10¨-5 |
2 |
|
|
90 |
|
|
|
4 |
a |
HCl
13% |
105¨50 |
0.5 |
STD |
STD |
20 |
|
|
b |
Cooling
water |
31¨39 |
3.5 |
|
|
40 |
|
|
|
5 |
a |
HCl
20% |
100¨ |
3 |
STD |
STD |
100 |
|
|
b |
Cooling
water |
20¨ |
3 |
|
|
150 |
|
|
|
6 |
a |
HCl |
50¨40 |
-200-0mmH2O |
STD |
STD |
200 |
|
|
b |
Cooling
water |
32¨37 |
2 |
|
|
250 |
|
|
|
7 |
a |
HCl
4% + acetic acid |
30¨20 |
4 |
STD |
STD |
25 |
|
|
b |
Cooling
water |
12¨ |
4 |
|
|
50 |
|
|
|
8 |
a |
HCl
+ sulfuric acid, etc. |
Design 15¨13.7 |
Design 10 |
STD |
STD |
50 |
|
|
b |
Ethylene
glycol 40% |
Design –10.6¨-9.5 |
Design 5 |
|
|
90 |
|
|
|
9 |
a |
HCl
+ sulfuric acid |
15¨13.7 |
10 |
STD |
STD |
50 |
|
|
b |
Ethylene
glycol 40% |
-10.6¨-9.5 |
5 |
|
|
90 |
|
|
|
10 |
a |
HCl
+ sulfuric acid |
75 |
10 |
STPG38 |
STD |
150 |
|
|
b |
Cooling
water |
60 |
5 |
|
|
200 |
|
|
|
11 |
a |
HCl
15% |
58¨30 |
3 |
STPG38 |
STD |
40 |
|
|
b |
Cooling
water |
25¨30 |
3 |
|
|
80 |
|
|
|
12 |
a |
HCl
corrosive liquid |
50¨ |
3 |
STPG38 Sch80 |
STD |
80 |
|
|
b |
Cooling
water |
5¨10 |
2 |
|
|
125 |