Manosys
Square Root Computer: EMRT1

|
Model |
EMRT1 |
|
Input Signal Output Signal *Output Cutoff Point Accuracy Temp. Drift Power Supply Outer Casing Operating Temp. Operating Humidity Insulation ResistanceVoltage Resistance Installation Weight |
4~20mA DC
(input resistance 50W) 4~20mA DC (load
resistance less than 500W) Less than 15%
F.S. Up to±1%F.S./ °C (at 20°C) Output signal: 15-100%F.S. Up to ±0.01%F.S./ °C (at 0-40°C) 100V AC±10% 50/60Hz Polycarbonate
and ABS resin 0~50°C (no icing) 90%Rh or less
(no condensation) Terminal to case:
over 20MW (500V DC megger) Power supply
terminal to case: 1000V AC
50/60Hz 1 min Rail
installation (35mm wide DIN rail) Approx. 300g |
* Output Cutoff Point
The cutoff point
is used to prevent square root extraction at between 0-15%
of the output signal. The reason
for this is that as the output signal decreases, input values become too small
for accurate calculation, as illustrated in the chart below. The cutoff point of 15% F.S. will not
interfere with the performance of the unit.
|
Output Value |
Input Value |
|
20% 15% 10% 5% |
(0.2)2 x 100%= 4% (0.15)2 x 100%= 2.25% (0.1)2 x 100%= 1% (0.05)2 x 100%= 0.25% |
For more information, please contact:
Mihama Corporation
E-mail: info@ mihama.com
Tel: +81-3-4570-3800
Fax: +81-3-4570-3803